High Pressure Steam Letdown High Pressure Steam Letdown
Steam erosion with some liquid cavitation can cause steam blowdown valves to experience body and trim damage.

Steam erosion with some liquid cavitation can cause steam blowdown valves to experience body and trim damage.

A significant amount of erosion is estimated to occur through clearance flow, which happens when the valve is closed and high pressure steam flows past the plug seals and seat. Certain materials are able to withstand these process conditions with little effect, while some may have significant damage. 

The standard hard-facing alloy for trim parts used in Emerson Fisher™ products have superior performance in these severe service conditions.

This material has a very desirable combination of properties such as high falling resistance, optimal metal/metal sliding wear resistance, corrosion resistance, high hot-hardness, high-temperature oxidation resistance, and excellent resistance to cavitation and flashing damage. Spartan also recommends a proper shutoff rated construction. The proper pairing of components and actuation allows for high quality performance in severe service conditions and significantly improved seal life and reliability.
Significantly improve seal life and reliability
Protect your critical assets
Choose products suited for the application